Loud 95dB audio
buzzer with a bright red LED and a relay trigger signals the alarm.
APPLICATIONS
-
AFR too rich
The alarm activates when too rich mixture is detected.
-
AFR too lean
The alarm activates when too lean mixture is detected.
-
A combination
of AFR too rich and AFR too lean alarms can be used to tune for
a specific AFR window.
-
EGT too high
The alarm activates when EGT exceeds a safe user selected level.
-
RPM too high
Shift-light functionality with a bonus of audio alarm and a
relay trigger.
-
TPS too high
The alarm activates when TPS exceeds a selected level.
-
USER1 Input too
high The alarm activated if a sensor connected to the USER1
input exceeds a selected level.
-
USER1 Input too
low The alarm activated if a sensor connected to the USER1 input
is lower than a selected level.
-
USER2 Input too
high The alarm activated if a sensor connected to the USER2
input exceeds a selected level.
-
USER2 Input too
low The alarm activated if a sensor connected to the USER2 input
is lower than a selected level.
-
Relay trigger
Open or close a relay circuit to activate or deactivate
additional devices at a set warning level. Typically used to add
a control to your boost setting, nitrous or alcohol injection
and other devices capable of engine destruction.
The Audio Visual Warning and Trigger Box alarm is activated by
Zeitronix Zt-2 Wideband AFR Meter. The audio alarm can be
deactivated by adjusting the switch SW1 inside the box. The visual
alarm and a relay trigger are always active.
The ZAVT-1 blue wire connects to the Zt-2 Warning Output (white wire
with a blue stripe).
SOFTWARE SETUP
Open the Zeitronix Logging
Software. Connect the Zt-2 Wideband AFR Meter into a PC COM port and
power up the Zt-2. Make sure the log graphs are shown on the screen.
Then open the Warnings and Triggers menu by selecting "Hardware"
then "Warnings:: Setup...".

Parameters can be selected for use in a Simple or a Complex Warning.
A Simple Warning will be triggered when any of selected
parameters exceed preset warning level.
A Complex Warning will be triggered when all selected
parameters exceed preset warning level.
In an example below a warning will be activated if the Boost exceeds
7 psi.
A warning will also be activated if the AFR mixture is leaner than
12.5 AND the RPM is greater than or equal to 6500.

Many other
warning combinations can be set by using the ZDL software.
The alarms are saved in the Zt-2 flash memory and kept after
disconnecting a PC laptop or disrupting power.
Zt-2s manufactured after Jan 22 2007 have additional alarm duration
feature, which keeps the alarm active after the alarm condition is
removed. The alarm duration can be setup between 0-240 seconds.
The Zt-2 has a single warning output wire. Simple and complex
warnings both activate the ZAVT-1 using this warning output wire.
OPTIONAL RELAY CONNECTION
The Zeitronix
ZAVT-1 box is capable of triggering an optional relay at a preset
warning level. Connect the ZAVT-1 WHITE wire ONLY to the negative
side of the relay; otherwise, leave the WHITE wire unconnected and
protected from accidental connection to any other signal.
Relay wire colors correspond to relays purchased from Zeitronix.

COMPATIBILITY
ZAVT-1 is compatible with the
Zt-2 Wideband AFR Meter REV 9 or higher. Zt-2s purchased after May 9
2006 are compatible and support Simple Warnings. Zt-2s purchased
after September 1 2006 support both Simple and Complex Warnings. You
can check the Zt-2 compatibility by accessing the warnings feature
in the Zeitronix Data Logging Software Version 2.0.8 or higher. To
do this open pen the Zeitronix Logging Software. Connect the Zt-2
Wideband AFR Meter into a PC COM port and power up the Zt-2. Make
sure the log graphs are shown on the screen. Open the Warnings and
Triggers menu (v2.0.18 or choose "warnings setup" from the
"Hardware" menu in the version 3 software. The following message is
displayed if an incompatible Zt-2 AFR Meter is detected.

 |